Send Message
Yixing Futao Metal Structural Unit Co. Ltd 86-510-87871161 li@fu-tao.com
33KV 18m Steel Utility Pole  Steel Power Poles With Insulator And Conductor

33KV 18m Steel Utility Pole Steel Power Poles With Insulator And Conductor

  • High Light

    electric utility pole

    ,

    steel power poles

  • Surface Treatment
    Hot Dip Galvanized
  • Material
    Hot Roll Steel Q345B, GR65
  • Height
    33kv 18m
  • Shape
    Round Or Polygonal
  • Wind Resistance
    160 Km/h
  • Powder Coated
    White, Blue, Sliver, Grey Or More
  • Thickness
    4.5mm
  • Place of Origin
    CHINA
  • Brand Name
    Futao
  • Certification
    ISO 9001
  • Model Number
    EP031
  • Minimum Order Quantity
    2 Pieces
  • Price
    $300 - $3,999.00/ Piece
  • Packaging Details
    40HC or OT, wrap by mat or straw mat
  • Delivery Time
    30-60 workdays
  • Payment Terms
    L/C, T/T
  • Supply Ability
    1200 pieces every month

33KV 18m Steel Utility Pole Steel Power Poles With Insulator And Conductor

                            33kv 18m steel power poles  steel utility pole with insulator and conductor

These specifications cover the design, engineering, manufacture, assembly, testing at manufacturer's works before dispatch of steel poles, cross arm assemblies, guy sets, danger plates, GI spike earthing sets for 33kV Single pole line, Suspension and Tension Fittings suitable for AAC Conductor for use on 3 phase, 50 Hz, solidly earthed 33kV Overhead lines.

  • The design and workmanship shall be in accordance with the best engineering practices to ensure satisfactory performance throughout the service life.
  • Any material and equipment not specifically stated in this specification but which are necessary for satisfactory operation of the equipment shall be deemed to be included unless specifically excluded and shall be supplied without any extra cost. Components having identical rating shall be interchangeable. The bidder has to furnish the testing facilities available at the manufacturer’s works.

ISO 20805:2005

Hot-rolled steel sheet in coils of higher yield strength with improved formability and heavy thickness for cold forming

BS 3288 : Part 1: 2018

Insulator and conductor fittings for overhead power lines. Performance and general requirements

ISO 10684:2004

Fasteners — Hot dip galvanized

ISO 10721

Steel structures

ISO 752:2004

Zinc

ASTM E350 - 18

Standard Test Methods for Chemical Analysis

ISO 657/V

1035/IV

Specifications For Rolling And Cutting Tolerances For Hot-Rolled Steel Products

ISO 12944-4:2017 Paints & Varnishes
ASTM A123 Recommended Practice for Hot Dip Galvanizing of Iron and Steel Articles
ASTM A123 Method of Testing Uniformity of Coating of Zinc;
ISO 1461:2009(en) Hot-Dipped Galvanized Coatings on Round Steel Wires
IEC 60335-2-71 Specification For Poultry Incubators
ASTM A90 Determination Of Mass Of Zinc Coating On Zinc Coated Iron And Steel Articles
IEC 60120 Dimensions of ball and socket couplings of string insulator units
IEC 60372

Locking devices for ball and socket couplings of string insulator units

- Dimensions and tests

IEC 61109 Insulators for overhead lines- Composite suspension & tension Insulators for A.C. systems with a nominal voltage greater than 1000V- definitions, test methods and acceptance criteria.
NFC 33-040 Suspension Equipment
NFC 33-041 Anchoring Devices

 

Whenever there is a difference in the Standards the most stringent criteria shall apply.

 

3.0 MATERIALS, CONSTRUCTIONAL DETAILS AND WORKMANSHIP

  • Materials used in the manufacture of all the equipment shall be new and best quality and class most suitable for performance under the specified conditions.
  • Steel used for manufacture of various equipment shall be in conformity with the general requirements relating to the supply of materials laid done in relevant international standards.
  • The material analyzed in accordance with ISO 13520:2015 or other relevant international standard shall not show sulphur and phosphorous contents of more than 0.060% each.
  • Equipment shall be well-finished, clean and free from harmful surface defects. Ends of steel poles, angle sections etc. shall be cut square and shall be straight.
  • The bolts, nuts & pack washers and guy wire strand & cross arm guard wire shall be hot dip galvanized as per ISO 1461:2009(en) or other relevant international standards. The quality of zinc shall be at least Zn 98 grade specified in ISO 752:2004. The zinc coating shall be adherent, smooth, reasonably bright, continuous and free from such imperfections and flux, ash and dross, inclusions, flake and black spot, pimples, lumpiness and runs.
  • The steel poles shall be hot dip galvanized with minimum 125 micron thickness of zinc coating and steel base plates with minimum 125 micron thickness of zinc coating generally as per ASTM A123 and tested as per relevant international standards..
  • The articles shall withstand minimum 4 dips of one minute duration. The uniformity of galvanized coating shall be determined by the preece test as prescribed in ASTM A123.
  • Suspension and Tension Fittings shall be made of Aluminum Alloy and all nuts and bolts shall be made of hot dip galvanized steel with minimum thickness of zinc coating of 85 micron as per ISO 10684:2004(en) Part XIII or other relevant international standards.

4.0 THE SPECIFIC TECHNICAL REQUIREMENTS OF VARIOUS EQUIPMENTS

4.1 Steel Poles

The purchaser may at its discretion furnish the design and fabrication data of one or more types of poles necessary for fabrication and testing of poles by the supplier or alternatively may ask the bidder to work out the optimum designs of poles and in that case submit detailed design calculations on ‘excel format’ for check and review by Employer.

Design of Poles shall be worked out and checked preferably as per ASCE Manual- 72 / SEI - 48- 05 or other relevant international standards. Poles shall be pre-drilled and supplied complete with pole top cap and base plate.

4.1.1 Specific Constructional Requirement

4.1.1.1 Poles shall be designed to withstand the worst possible combination of simultaneous loading of

  • Lateral loads consisting of wind forces on conductors corresponding to wind spans, wind force on insulators, wind force on pole and maximum conductor tension.
  • Vertical loads consisting of pole self-weight, weights of conductors, insulators, cross-arm, additional equipment, lineman and compressive force due to reaction of stays wherever applicable.

4.1.1.2 Steel poles for HV (33 kV), HV / LV mixed shall be worked out for the following types and applications

  • Contractor shall submit the detailed design & drawing of pole for each above said 33kV Transmission line for approval of Client and sample drawing showing dimension & configuration are enclosed.
  • Poles shall satisfy the dimensional length and pole top loading requirements as per the design parameters listed in this specification. The dimensions across flats for top and bottom for all poles are listed in this specification/drawings as a preferred design to utilize one dimension for each type of pole length in so far as design & working load criteria is met.

4.1.1.5 Working Load

Working Load of a pole specified herein and defined as the load which when applied at 250 mm below top will induce the maximum permissible stress in the pole, shall be marked on each pole.

  • The standard poles shall be suitable for the specified applications based on the design parameters given in Table 2, 3 & 4.
  • A through hole of 14 mm diameter shall be provided in each pole at a height of 300 mm above the planting depth for earthing. The location of hole at a height of 300 mm shall be got approved from the Employer before manufacturing of the poles.

4.1.1.11 Design Parameters and Factor of Safety

 

 

Span (m)

Basic 100
Wind 110
Weight 150
Wind pressure (N/m2) On pole 1200
On conductors at 10°C 600

 

 

 

Factor of Safety

Vertical loads 1.18
Transverse loads 1.8
Longitudinal loads 1.8
Ultimate load 1.8
Conductor minimum breaking strength 3.0
Planting Depth (m) 1.6
Allowable Deflection at Pole Top 5% of expose length

 

Stay wires

Minimum Breaking Load 101kN
Max. Tension 90% of min. breaking load
Min. angle to the pole 37°

 

Temperature

Minimum 0°C
Maximum +40°C

 

 

Tolerances

 

i. Length

The tolerance on the length shall be as follows:

 

i. - Length of any section + 40 mm

 

ii.

- Overall length of pole

Straightness

+ 25 mm

The finished pole shall not be out of straightness by more than 1/600 of its length.

 

The rolling and cutting tolerance for hot rolled steel products shall be in accordance with relevant international standards.

 